Overall, the sub-challenge can be divided in two different tasks:
- Nds Surgical Imaging Driver Download
- Nds Surgical Imaging Driver Download Mac
- Nds Surgical Imaging Driver Download Free
Imaging technology used to diagnose illness and injury is increasingly being used to assist surgeons complete procedures. Image-guided surgery involves the use of a real-time correlation of the operative field to preoperative imaging data that reflect the precise location of a surgical instrument to the surrounding anatomical structures. NDS Surgical Imaging is the global leader in designing and manufacturing surgical displays and advanced imaging technologies. The use of interactive planning and patient specific guides streamline the surgical workflow. Technology is a significant driver for patients to undergo total joint replacement surgery. 1 Studies have demonstrated better accuracy and clinical outcomes through the use of Patient Specific Guides. Barco's medical display controller series takes performance, longevity and workflow support required for your PACS workstation to the next level. The boards support higher refresh rates and resolutions than their predecessors to ensure compatibility with evolving protocols and modality requirements.
NDS Surgical Imaging North American Corporate Headquarters 5750 Hellyer Avenue San Jose, CA 95138, USA 1-866-637-5237 info@ndssi.com ©NDS Surgical Imaging, a Novanta Company.
1.) Segmentation: Can you segment the surgical instruments in an endoscopic image?
2.) Tracking: Can you track the surgical instruments in an endoscopic image sequence?
Data is provided for rigid and articulated robotic instruments in laparoscopic surgery. For rigid instrument trakcking, the data reflects typical challenges in endoscopic vision like occlusion, smoke and bleeding. For robotic instrument tracking, the instruments show typical poses and articulation in robotic surgery and there is some occlusion but no smoke and bleeding in any sequence.
The data is split into a training and test set (see below). Please read the instructions in the 'Readme' file provided with each data set.
Nds Surgical Imaging Driver Download
Rigid Instruments | Robotic Instruments | |
---|---|---|
Segmentation | 40 2D in-vivo images from 4 laparoscopic colorectal surgeries. Each pixel is labelled as either background, shaft and manipulator (~160 2D images and annotations in total). | 4 45-second 2D images sequences of at least one Large Needle Driver instrument in an ex-vivo setup. Each pixel is labelled as either backgroud, shaft, head or clasper. |
Tracking | 45 seconds in-vivo video sequences of 4 laparoscopic colorectal surgeries together with pixel-wise labelling of the instrument, (x/y) position of the center point of the end of the shaft and instrument axis in one frame every second as reference (~4500 images and 180 annotated images) | 4 45-second 2D images sequences of at least one Large Needle Driver instrument in an ex-vivo setup. For each frame the associated 2D pose (rotation, translation and articulation of head and claspers) is provided. |
Rigid Instruments | Robotic Instruments | |
---|---|---|
Segmentation |
|
|
Tracking |
|
|
Nds Surgical Imaging Driver Download Mac
Nds Surgical Imaging Driver Download Free
Rigid Instruments | Robotic Instruments | |
---|---|---|
Segmentation | For evaluating the instrument segmentation, the DICE coefficient between the reference and the submitted result is used. Furthermore, typical classification metrics like precision and recall are calculated. | For evaluating the instrument segmentation, the DICE coefficient between the reference and the submitted result is used. Furthermore, typical classification metrics like precision and recall are calculated. |
Tracking | For evaluating the rigid instrument tracking, the reference segmentation is used. As error measure, the Euclidean distance between center point of the end of the shaft and the estimate of this point is used. Furthermore, the angle between the axis of the instrument and the estimated axis is used. | For evaluation robotic instrument tracking, the Euclidean distance between the end of the shaft and the estimate of the shaft end is calculated as well as the rotation of the shaft. To assess the articulation estimation accuracy the absolute distance of rotation error is used. |